HY InfiniSolar WP Three Phase On-Grid Inverter15 KVA

  • IP21 waterproof and dustproof makes the inverter available for various working conditions.
  • Built-in Wi-Fi for mobile monitoring (App is available)
  • 150% unbalanced load support
  • Optional dual outputs for smart load management (check sales)
  • Built-in AS coupled function
  • User-adjustable charging current and voltage
  • Reserved communication port for BMS (RS485)
  • Parallel operation up to 6 units

MODEL 15KW
MAXIMUM PV INPUT POWER 16000 W
RATED OUTPUT POWER 15000 W
MAXIMUM CHARGING POWER 15000 W
GRID-TIE OPERATION  
PV INPUT (DC)  
Nominal DC Voltage / Maximum DC Voltage 720 VDE / 1000 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 350 VDC ~ 950 VDC
Number of MPP Trackers / Maximum Input Current 2 / A: 26A, B: 26A
Number of Strings Per MPP Tracker A: 2, B: 2
GRID OUTPUT (AC)  
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184-265 VAC per phase
Norminal Output Current 21,7 A per phase
Power Factor Range 17.4 A per phase
EFFICIENCY  
Maximum Conersion Efficiency (DC/AC) >96%
European Efficiency@ Vnominal >95%
OFF-GRID OPERATION  
AC INPUT  
AC Star-up Voltage / Auto Restart Voltage 120 -140 VAC / 180 VAC
Acceptable Input Voltage Range 170 -290 VAC per phase
Maximum AC Input Current 40 A
PV INPUT (DC)  
Maximum DC Power 22500 W
Maximum DC Voltage 1000 VDC
MPP Voltage Range 350 VDC ~ 950 VDC
Number of MPP Trackers / Maximum Input Current 2 / A: 26A, B: 26A
Number of Strings Per MPP Tracker A: 2, B: 2
BATTERY NODE OUTPUT (AC)  
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure sine wave
Efficiency (DC to AC) 91%
HYBRID OPERATION  
PV INPUT (DC)  
Maximum DC Voltage 320 VDC / 350 VDC
Start-up Voltage / Initial Feeding Voltage 350 VDC / 850 VDC
MPP Voltage Range 2 / A: 26A, B: 26A
Number of MPP Trackers / Maximum Input Current A: 2, B: 2
GRID OUTPUT (AC)  
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 – 265 VAC per phase
Nominal Output Current 21,7 per phase
AC INOUT  
AC Star-up Voltage / Auto Restart Voltage 120 – 140 VAC / 180 VAC
Acceptable Input Voltage Range 170 – 290 VAC per phase
Maximum AC Input Current 40 A
BATTERY NODE OUTPUT (AC)                                         
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC) 91%
BATTERY & CHARGE
Battery Voltage Range 40 ~ 62 VDC
Maximum Charging Current 300 A
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 255 x 660 x 750
Net weight (kgs) 73
INTERFACE
Communication Port RS-232, RS-485, USB, CAN and Wi-Fi
Intelligent Slot Optional for SNMP and Modbus cards
ENVIRONMENT
Humidity 0 ~100% RH (Non-condensing)
Operating Temperature -25 to 60℃, >45℃ power derating